Steam or hot water: which system do you have.
A steam boiler heats water to steam, which rises through pipes to radiators, and returns as condensate. It has a sight glass showing water level. A hot water boiler circulates heated water through pipes to radiators, baseboards or in-floor loops. It has a pressure gauge, not a sight glass.
Many older Chillicothe houses have one or the other, and they fail differently. The first thing we ask on the phone is which you have.
Boiler symptoms and what they point to.
The sound or sign narrows the search.
| Symptom. | Likely cause. | Typical fix. |
|---|---|---|
| Leaking from the boiler. | Failed gasket, relief valve or cracked section. | Replace the part, or the boiler if the vessel leaks. |
| Banging pipes (steam). | Water trapped in a pipe, bad pitch. | Fix the pitch, clear the trap, check the vents. |
| No heat, boiler cold. | No fuel, ignition fault or tripped switch. | Test the ignition and controls. |
| Short cycling. | Oversized boiler, dirty sensor or low water. | Clean sensors, check water level and thermostat. |
| Radiators cold at the top. | Air trapped in the system. | Bleed the radiators or vents. |
| Low pressure (hot water). | Leak or failed expansion tank. | Find the leak, replace the tank. |
Boiler leaking or not heating? Call and tell us the make, age and symptoms.
Call (855) 575-2890Leaks and water level problems.
Boiler leaks are often at a gasket, a circulator flange or a relief valve. These are repairable. A leak from the boiler body, particularly at a section joint on a cast iron boiler, usually means replacement.
On a steam boiler, low water can damage the unit. Check the sight glass. If it is empty, turn off the burner and call.
If you add water often, the system is leaking somewhere. A dry boiler room does not mean there is no leak, since leaks can be in the walls or buried in a slab.
A boiler service visit.
Safety check.
We check the combustion, venting and gas connections.
Diagnose.
We test controls, circulators, valves and pressure.
Repair.
We replace failed parts or advise when replacement is better.
Test and record.
We run a heating cycle and give you notes on what to watch.
Maintenance before the cold season.
Boilers do best with an annual check before winter. A steam boiler needs its low water cutoff flushed. A hot water boiler needs its expansion tank and air vents checked.
A boiler that runs without issues for years can stop on the coldest night. A fall check is cheaper than an emergency call.
Repair or replace.
A boiler can last decades, and many in older homes do. When parts are scarce, efficiency is poor or the heat exchanger leaks, replacement is the better value.
We give you a clear comparison, including the cost of keeping the old one running.
Boilers in older Ross County homes.
Boilers are common in older homes in Chillicothe, particularly those with radiators. Winters in southern Ohio are cold enough to test them for months. Pipes in unheated basements, garages and crawlspaces freeze, and a frozen boiler line can burst.
If your boiler room is in a basement that has flooded in the past, tell us. Controls and burners that have been under water need replacement.
What affects boiler repair pricing.
We quote before parts are ordered.
- Part and system type. Steam and hot water parts differ.
- Boiler age and access. Older units may need special parts.
- Combustion testing. Extra time for safety checks.
- Hour of the call. Winter weekend calls cost more.
A failed boiler that freezes pipes may lead to a claim. Keep records of maintenance, since insurers may ask.
Standards behind boiler work.
Boilers follow the manufacturer's service instructions and the NFPA 54 National Fuel Gas Code for gas piping and venting. Pressure relief valves are a safety device and are not adjusted to chase a symptom. Ask any contractor which manufacturer instructions they are following for your model.
What to do before we arrive for a boiler problem.
Boilers combine gas, heat and pressure, so go slowly.
- If you smell gas, leave the house and call 911 or your gas supplier before anything else.
- Do not touch the relief valve or any pressure fitting.
- Turn the thermostat down so the boiler stops calling for heat.
- Note the pressure gauge reading and any error code, and read them to the person on the phone.
- Keep the area around the boiler clear and dry.
Boiler repair questions answered.
.
Whether boilers can be handled in the evening or on a weekend is confirmed when you call (855) 575-2890, and it is not promised in advance. Describe what is happening and ask what can be arranged. Meanwhile, turn the unit's gas or power to off and close its cold-water inlet valve.
.
Air is trapped. Bleeding the radiator or checking the vents usually fixes it.
.
There may be a leak or a failed expansion tank. Check the pressure gauge, which should sit in a normal range on the label.
If it keeps dropping, call.
.
Once a year before the heating season.
.
We replace and repair boilers in homes. For large commercial systems, we tell you in advance if the job is beyond us.